The Engine That Grades Its Own Homework: PIQI as FHIR Resources, Measured on Real ICU Data
Every healthcare data vendor asserts data quality. Almost nobody measures it — against a defined framework, on their own data, with numbers you can check. Assertions are marketing; a scorecard is a receipt.
This post is about a data-quality engine that grades its own homework. It implements the Patient Information Quality Improvement Framework — PIQI, pronounced "picky" — not as code but as FHIR resources, so every quality check is an inspectable, forkable artifact. Then, to prove it measures something real, we pointed it at MIMIC-IV-FHIR: a baseline scorecard on genuine ICU data, one honest intervention (auto-coding), and a re-score against ground truth we manufactured by removing codes we already had.
PIQI in one section
PIQI comes from the PIQI Alliance (Charles Harp's framework guides, v1.1/v1.2), and its core move is to make "data quality" decomposable instead of vibes. Four quality dimensions, each with sub-classifications: accuracy (is the value right?), conformity (does it obey the rules of its type and structure?), availability (is it there at all — populated, complete?), and plausibility (is it believable — a 3,000 mmHg blood pressure is well-formed and populated and wrong).
The unit of measurement is the SAM — a Simple Assessment Module: a pass/fail check bound to a data attribute. Attr_IsPopulated on a lab value, Concept_HasCode on a coded concept, Attr_IsNumeric on something that must parse as a number. Each SAM declares its scoring effect, an optional weight, and an optional criticality flag.
Here is the dimension taxonomy with a sample of the SAMs we ship against each sub-classification:
| Dimension | What it asks | Sub-classifications (with sample SAMs) |
|---|---|---|
| Availability | Is the data there at all? | • Unpopulated — Attr_IsPopulated• Incomplete — Concept_IsComplete, Concept_HasDisplay• Missing — ObservationValue_HasType• Duplication — Class_HasDuplicates |
| Accuracy | Is the value right for its type? | • InvalidValue — Attr_IsNumeric, Attr_IsDecimal, Attr_IsTimestamp, Attr_MatchesRegex, Attr_InList• InvalidFormat — Attr_IsValidDate |
| Conformity | Does a coded concept obey its type system? | • InvalidMember — Concept_HasCode, Concept_HasCodeSystem, Concept_HasRecognizedCodeSystem |
| Plausibility | Is the value believable? | • TemporallyImplausible — Attr_IsFutureDate, Attr_IsPastDate• ClinicallyImplausible — LabResult_ValueIsPlausible, LabResult_UnitIsPlausible, Condition_SexPlausible |
(A full inventory of the 33 implemented SAMs — including the terminology-dependent ones like code-system membership and display-consistency — ships with the library; the four not yet implemented are documented with reasons in the project's completeness matrix.)
A rubric is an ordered, weighted set of SAMs scoped to data classes (conditions, medications, lab results, demographics…). Run a rubric over a payload and you get a scorecard: the PIQI Index (0–100, passed items over scorable items), a weighted variant when the rubric weights SAMs, a critical failure count for SAMs flagged critical, and a Data Class Frequency breakdown so you can see which classes dragged the score. One thing the framework deliberately does not give you is interpretive bands — there is no universal "75 is good." A score means what its rubric makes it mean; comparison is rubric-relative. That's a feature: it forces you to say what you care about.
The implementation: PIQI as FHIR resources
Here is the part we think is genuinely new. Most quality frameworks live in code — a Python package, a rules engine, a vendor product. Ours lives in data:
- Every SAM is a ViewDefinition (SQL-on-FHIR v2) that defines the extraction shape — which elements of which resources constitute the population under assessment — composed with a SQLQuery Library (the analytics-layer profile) that carries the pass/fail predicate.
- Rubrics are SQLQuery Libraries whose
relatedArtifactdependencies point at the SAM queries they weigh and order. - Execution runs through the standard fhir4ds SQL-on-FHIR analytics layer — zero custom runtime. If you can run a ViewDefinition, you can run a PIQI scorecard. Scoring is deterministic, and every result carries provenance: which SAM fired, on which elements, with what evidence — an audit trail, not a verdict from a black box.
We implemented 33 of the 37 guide-defined SAMs, which per the guides is a complete implementation with documented exclusions (the remaining four are builder-trivial-unbound or RESTful-surface checks). Because the whole thing is resources, anyone can inspect a rubric, re-weight it for their own priorities, and fork it — the framework's rubric-relativity made mechanical.
Two integrations matter in practice. Every verdict feeds a curation queue: near-misses and vocabulary-unmatched resources get routed for human review instead of silently bucketed. And the scorecard is attributive — it doesn't just say "38," it says which SAMs failed on which classes, which is what makes it an engineering instrument rather than a grade.
The self-measuring engine, demonstrated on MIMIC
To show the engine measuring something real, we ran it against MIMIC-IV-FHIR — the Beth Israel ICU dataset converted to FHIR R4, 100 patients, roughly 900K resources of genuinely messy clinical content — through our deterministic, seeded realism harness (fhir4ds.realism). No synthetic corpus here: real UCUM oddities, real local code dictionaries, real missingness.
The honest baseline
The scorecard on a 12-patient slice (86,224 resources, 98,202 scored items) read 38.5 on the broad default rubric — and 23.2 on the coding-centric rubric. Low numbers, but read the attribution before judging: the deductions are dominated by genuinely absent lab values and units (Attr_IsPopulated failing on 74,667 items), the real-world incompleteness synthetic corpora never model. The scorecard isn't wrong; the data is incomplete, and the scorecard correctly attributes the problem. That's the difference between a measurement and an insult.
A second self-measurement from the same corpus: deduplication over the full export found 46,469 duplicate clusters — all real repeated clinical events, none injected — with zero cross-patient clusters, the hard safety invariant.
One intervention, measured honestly: auto-coding
Then we changed one thing and re-ran the identical scorecard. The intervention: the medterm4ds auto-coder, which augments text-only CodeableConcepts with standard terminology codes (skipping concepts already coded in standard terminologies).
The medication story is the cleanest. MIMIC ships medications as name-codes — the coding's code literally is the drug name ("Ondansetron") under a private system, no display, no standard vocabulary. Measured on the coding columns: zero of 2,429 medication requests recognized, displayed, or complete before. After auto-coding, 360 carry RxNorm codings — recognition, display, and completeness moving together, local drug names becoming addressable standard terminology. The auto-coder is conservative by contract: it refuses when it isn't confident, and every generated coding carries machine-readable provenance (engine, version, search mode, score, match grade, userSelected=false).
A procedure, worked through. The clearest single illustration of the auto-coder behaving exactly as designed: a MIMIC procedure coded 4311 — "Percutaneous [endoscopic] gastrostomy [PEG]" under a wrapper system — classic bracketed ICD-9 billing shorthand. The environment alias already recognizes it as ICD; the auto-coder then appends SNOMED 235159007 — Percutaneous endoscopic gastrostomy, along with a second candidate (312341002, the permanent PEG variant) at a lower grade. The original ICD coding is untouched. Every appended coding carries userSelected=false and full provenance — engine version, search mode, score, match grade, and which text it searched on. A billing-coded legacy procedure becomes a clinically-coded one without losing anything, and a terminologist reviewing the two candidates has everything needed to confirm or dismiss in seconds. That is the contract working: augment, never overwrite; suggest, never assert.
What auto-coding can and cannot recover falls into a clean three-tier taxonomy:
| tier | population (n) | recognized before → after |
|---|---|---|
| already standard | procedures with SNOMED originals (224 of 494) | recognized as-shipped; auto-coding adds nothing |
| alias-recovered | conditions and procedures under MIMIC's wrapped ICD systems (669 + 121) | 0 → 669 conditions (100%); procedures 224 → 345 via environment aliases |
| translation-required | medications as local name-codes (2,429) | 0 → 0 without help; auto-coding moves 360 to RxNorm |
The conditions tier has its own lesson. MIMIC's ICD-9/10 codes sit under wrapper URIs, so they initially scored as unrecognized — fixed not by code but by an environment alias, a declarative table mapping wrapper URIs to their standard ICD counterparts, consulted after the standard-registry spellings. With aliases registered, every ICD condition is recognized before auto-coding touches anything; what auto-coding adds there is portability (SNOMED equivalents any consumer trusts) and clinical semantics, not a recognition delta.¹
The text-gate finding. PIQI as scored shows no movement in that production arm — and that is itself a result. The packaged Concept assessments are gated on code.text being populated, and MIMIC ships none. The scorecard told us exactly where the problem lives: value in the coding columns, silence in the scored column. (The scorecard also caught us: an earlier run under-counted recognized procedures because ICD-10-PCS was missing from the standard code-system registry. The engine grading its own homework includes grading ours.)
(How accurate is the auto-coder when you do know the right answer? We ran a companion experiment — strip the codes, reconstruct them from text, score against the removed originals — with clean results worth their own post.)
Ship it
The whole loop ships in fhir4ds: PIQI rubrics as resources, the realism harness (fhir4ds.realism) and the PIQI auto-coding benchmark (fhir4ds.realism.piqi_autocoding) — deterministic, repeatable, corpus-agnostic. Point them at your own exports. The interesting bugs are the ones your test data doesn't contain, and the scorecard will tell you exactly where they live.
¹ The alias table ships as data in the PIQI code-system registry; a different environment registers its own wrappers without code changes, and recognition through an alias is distinguishable from a standard spelling in the verdict's provenance.